Security alert · High
N-able N-central: crypto-miner attacks reported, only a workaround so far
· 3 minutes read · Centoculus Security Team
Known since · attacks confirmed since
Affected: N-able N-central (affected versions not named in the available data)
What happened
On 15 November 2026, heise online reported that attackers are targeting N-central, the remote monitoring and management product from N-able, and that crypto-miner attacks have been observed. According to the report, the attacks use a new attack path. N-able has no patch for it yet, only an interim workaround.
The data available to us does not name the attack path, the affected versions or the details of the workaround. It also does not say how many installations are affected. Check N-able's official advisories and support channels for the exact workaround and for news about a patch.
Who is affected
Operators of N-able N-central, typically managed service providers and agencies that use it to manage customer servers and workstations. The available data does not list which N-central versions are affected, so treat every N-central installation you run as at risk until N-able says otherwise.
If you do not run N-central, this alert does not concern you. Web servers, PHP, CMS installations and hosting panels are not affected.
An RMM server usually has administrative access to many managed systems. Beyond the crypto-miners that were reported, a compromised N-central server can therefore put the systems it manages at risk.
What to do now
- Find N-able's current advisory or support notice on this issue and apply the interim workaround it describes on every N-central server you run.
- Until a patch is available, make the N-central server reachable from as few places as possible, for example only from known IP addresses or through a VPN, as far as your setup allows.
- Check your N-central servers for signs of compromise (see below). If you find any, treat the server as compromised: isolate it, review the systems it manages and rebuild it from a known-good state.
- Follow N-able's announcements and install the patch as soon as it is released.
How to check whether you are affected
- Look at CPU load on the N-central server and on managed systems. Constant, unexplained high load is a typical sign of a crypto-miner.
- Look for unknown processes, services, scheduled tasks or cron jobs, and for recently created executables or scripts.
- Look for unusual outgoing connections, especially long-lived connections to mining pools or unknown hosts.
- In N-central, look for unknown user accounts, changed permissions and scripts or jobs that nobody on your team created or ran.
- Check access logs for unusual requests or logins from unknown IP addresses since mid-November 2026.
Update November 17, 2026
N-able has released N-central 2026.4 Hotfix 3, which it calls a critical security update. According to The Hacker News, it fixes 17 more N-central flaws, removes the legacy APIs and asks customers to upgrade their Agents and Probes as well. heise reports that the crypto-miner attacks only hit instances where the Legacy API was enabled, which is off by default. The researchers counted 21 compromised servers, and 19 of them were already running Hotfix 2, so Hotfix 2 alone does not protect you.
-
Install N-central 2026.4 Hotfix 3 on every on-premises N-central server, then upgrade Agents and Probes as N-able recommends.
-
Until Hotfix 3 is installed, keep the Legacy API turned off.
-
If the Legacy API was ever enabled, look for Monero miners and the other signs of compromise listed above, even on servers that already have Hotfix 2.
-
https://thehackernews.com/2026/11/n-able-patches-17-n-central-flaws-as.html
Sources
Related posts
Alerts ·
WordPress plugin vulnerabilities: 8 plugins, including WPvivid Backup
Vulnerabilities in eight WordPress plugins were disclosed on 20 November 2026, among them WPvivid Backup, NextGEN Gallery and Optimole. The most serious, in Mang Board, lets unauthenticated visitors delete board posts.
Alerts ·
Drupal core: critical installer flaw can allow site takeover without login
Drupal fixed a critical flaw in the built-in installer (install.php). Under specific conditions it lets attackers without a login reinstall a site and take it over. Update to 10.6.22, 11.3.22 or 11.4.13, and block the installer.
Alerts ·
VMware vCenter Server: critical authentication bypass fixed after zero-day attacks
Broadcom has fixed a critical authentication bypass in VMware vCenter Server (VMSA-2026-0009). Mandiant says it was used in zero-day attacks from early September 2026. vCenter 8.0, 9.0 and 9.1 are affected. ESX hosts are not.